An instrument of World of AI  ·  planetAI LLP ← The atlas·HARMONIA·Assay
GREEN‑LLM Index  ·  v1.7  ·  planetAI LLP
Field instrument for AI environmental accounting

How green is
your LLM usage?

Every prompt draws power, carbon and water. This instrument measures five dimensions of that draw, places your usage on a decision matrix, and scales the result to a planetary view. Set the dials to match how you actually work.

Verdancy reading
ECritical
DWasteful
CAcceptable
BEfficient
ARegenerative
—/100
—

01 — Inputs

Describe your usage

30
600
12K
1
02 — Readings

What your usage draws

Energy / query
—
Wh at the meter
Carbon / query
—
g CO₂e
Water / query
—
millilitres
Your annual carbon
—
kg CO₂e per year

03 — The equation

Show the working

No black box. Here is the exact arithmetic behind the readings above, with your own numbers substituted into every term. If you disagree with a coefficient, change the input and watch the chain re-derive.

EIT  =  ( Tout · δ  +  Tin · π )  ·  C  ·  (1 + R)
Esite  =  EIT  ·  PUE
CO2e  =  Esite  ·  Igrid      H2O  =  Esite  ·  ( Wsite + Wgen )

Where the energy goes Energy flow from prompt to atmosphere and water

04 — In context

What one of your prompts equals

Carbon comparison of one query against everyday activities

05 — The score

Five dimensions, one hundred points

06 — The matrix

Carbon cost against value created

Value created →
Quadrant I

Regenerative

Low draw, real displacement. This is the pattern to scale and standardise across the organisation.

Quadrant II

Justified load

Heavy, but it earns its keep. Optimise the infrastructure and routing rather than cutting the use.

Quadrant III

Ambient drift

Individually negligible, collectively enormous. Trim through defaults and smaller models, not policing.

Quadrant IV

Carbon waste

Expensive compute producing little. Eliminate first — this is where the fastest reductions live.

Carbon cost per task →

07 — Rubric

The scoring matrix

DimensionLevel 1 — CriticalLevel 2 — WastefulLevel 3 — AcceptableLevel 4 — EfficientLevel 5 — Regenerative
G — Generation
footprint
25 pts
Above 8 g CO₂e per task. Untracked, unmeasured. 2–8 g. Estimated once, never revisited. 0.5–2 g. Measured quarterly at portfolio level. 0.05–0.5 g. Per-workload telemetry in place. Under 0.05 g, with per-request attribution to a named owner.
R — Right-
sizing
25 pts
One frontier model for everything, including formatting. Manual model choice, biased to the largest available. Documented guidance on which model suits which task. Tiered routing with a small-model default and escalation rules. Automatic complexity routing, cascade fallback, measured accuracy floor.
E — Interaction
efficiency
20 pts
Three or more re-prompts typical; whole history resent each turn. Frequent retries; no caching; unbounded output. Some prompt templates; occasional context pruning. Prompt library, output caps, prefix caching enabled. Single-pass success as a tracked metric; retrieval instead of resent context.
E — Energy
provenance
20 pts
Unknown region, unknown PUE, water-cooled in a stressed basin. Fossil-heavy grid, PUE above 1.5. Regional average grid, PUE near 1.4, annual REC matching. Low-carbon region, PUE under 1.3, closed-loop cooling. Hourly carbon-free matching, PUE under 1.15, near-zero potable water draw.
N — Net value
displaced
10 pts
Entertainment and novelty at production volume. Convenience gains only; no measurement attempted. Claimed productivity benefit, anecdotally evidenced. Measured hours or defects avoided, tied to a baseline. Verified displacement of a higher-carbon activity, audited.

How to read it. Score each row independently, then sum. The weighting is deliberate: right-sizing and generation footprint carry half the total because model selection is the single largest lever a user controls — larger than grid choice for most organisations, and available immediately.

08 — Levers

What moves the needle for you

Reductions are modelled against your current settings and are not additive — each assumes the others stay as they are.

09 — Model selection

Which model is greenest for this workflow?

The greenest model is not the smallest one — it is the smallest one that clears the quality bar, because a model that fails the task pays full price twice. Describe the workflow, and every candidate is costed on money, carbon and capability together.

120K
2,500
400
$85

ModelTier$/M in$/M out $ / 1K taskskg CO₂e / 1K tasks Annual costAnnual tCO₂eGreenAbatement $/tCO₂e

Why the abatement figures are so large. At realistic volumes the money saved by switching models outweighs the carbon saved by three to five orders of magnitude in dollar terms. That is not a rounding error — it is the central strategic fact on this page. No plausible carbon price will ever drive model selection, so do not build the business case on carbon. Build it on cost, and bank the emissions reduction as a consequence. Sustainability programmes that depend on a carbon price to justify themselves lose the budget argument; cost-reduction programmes that happen to cut emissions survive it.

Figure F · Cost against carbon, with the efficient frontier Scatter of models by cost and carbon per thousand tasks

Calculation logic — every term, in order
  1. Effective attempts. A model one capability tier below the workflow requirement is assumed to need one extra attempt; two tiers below, two extra. A = 1 + max(0, tier_required − tier_model). This is what stops the cheapest model winning by default.
  2. Cost per task. $ = (T_in · P_in + T_out · P_out) ÷ 1,000,000 × calls × A, where calls is 1 for chat-style work and higher for agentic archetypes.
  3. Energy per task. Wh = (T_out · d + T_in · p) × calls × A, using the decode and prefill coefficients for the model's size class from section 03.
  4. Carbon per task. gCO₂e = Wh ÷ 1000 × PUE × I_grid, taking PUE and grid intensity from your settings in section 01.
  5. Annualised. Multiply both by tasks per month, then by twelve.
  6. Marginal abatement cost. MAC = (Cost_model − Cost_baseline) ÷ (CO₂_baseline − CO₂_model), in dollars per kilogram of CO₂e avoided. A negative MAC means the switch saves money and carbon at once — a no-regret move that needs no sustainability budget to justify. A positive MAC is the real price of that abatement, and should be compared against your internal carbon price before you claim it as a green initiative.
  7. Green score. The five dimensions from section 05, recomputed per model with the workflow's token profile and the attempt penalty applied.

Two warnings before this drives a procurement decision. First, list prices move constantly and the defaults here reflect published rates around August 2026 — verify every row against the provider's current rate card, and note that batch processing and prompt caching can each cut the cost column substantially without changing the carbon column much. Second, the capability tiers are a coarse judgement, not a benchmark result: the honest version of this table is one where you have run your own evaluation set and replaced the tier column with your own pass rates.

10 — The agent

Requirements agent

Sections 01 to 09 tell you where you stand. This tells you what to do. You have set roughly a dozen dials across this page — model, region, facility, tokens, workload. There are hundreds of valid combinations and no human picks the best one by eye. The agent does it arithmetically, and shows its working.

Step 1 — it checks

Reads every input you have set and looks for contradictions: a real-time promise on a workflow that cannot be real-time, a retry rate that signals a broken prompt, evaporative cooling on a coal grid. It tells you what is wrong before it recommends anything.

Step 2 — it searches

Enumerates every combination of model, region, facility efficiency, cooling, prompt caching, batching and output policy that your constraints permit — typically several hundred — and scores each on carbon and cost together.

Step 3 — it recommends

Returns one deployable configuration, the projected annual cost and carbon against your current baseline, and an eight-line trace of how it got there — including the runner-up, so you can see whether the decision was close.

A worked example of the value. On a support-triage workflow at 120,000 tasks a month, most teams default to a mid-tier frontier model on whatever region their cloud account defaults to. The agent typically finds a smaller model that clears the same quality bar, on a cleaner grid, with a tighter output cap — and returns something in the order of a few thousand dollars and a fraction of a tonne of CO₂e saved a year, for the same work. Run it and read the numbers for your own settings rather than mine.

Set the four constraints below to describe what you are actually allowed to change. If you are unsure, the defaults are the common enterprise case.

Where the law or your contracts say inference may physically run. Picking a region is the single biggest carbon lever — if you cannot move, say so and the agent will stop offering it.

How fast the answer must come back. Batch tolerance unlocks a fifty per cent cost cut; real time rules out multi-step agents entirely.

How much quality you will trade for savings. Strict protects the answer; cost-first accepts a weaker model and pays for the extra attempts it needs.

50 / 50

← all carbon  ·  all cost →

Which you care about more when the two disagree. They usually agree — slide it to both ends and see whether your answer even changes.

Run the agent Takes about a second. Nothing is sent anywhere — the search runs entirely in your browser.
11 — Projection

If the world worked the way you do

Your per-query figures, scaled to a planetary user base. Adjust the assumption and watch the sensitivity — the honest finding of this exercise is how much the answer depends on inputs nobody publishes.

5 bn
2.5×
Each square = 1% of projected 2030 data centre demand (9.5 TWh)
Your profile, scaled worldwide Remaining 2030 headroom Beyond the 2030 projection

Read the gap, not just the number. For ordinary chat usage this projection lands well below actual data centre consumption — and that gap is the finding. Serving prompts is only a slice of AI's footprint; training runs, idle capacity held warm for latency, networking, storage and the embodied carbon of chips and buildings make up the rest. Push the model class to agentic and the gap closes fast, which is the clearest signal in the whole instrument: workload design, not chat volume, is what will decide AI's environmental trajectory.

12 — Equilibrium

In the race to adopt AI, are we missing the environment?

Partly, and in a specific way. The environment is not being ignored — it is being measured on the wrong axis. Efficiency per task is celebrated because it is improving spectacularly. Total load is downplayed because efficiency is improving spectacularly. Both are reported honestly and the combination is misleading, because the quantity that decides the outcome is neither one alone: it is whether workload growth, net of efficiency, outruns the growth of clean supply.

Figure D · What the race actually measures

The asymmetry is the finding. Capital, compute and demand are all compounding at double or triple digits. The one line that has not moved is disclosure — not a single frontier lab publishes full per-model energy telemetry, which is why every framework on this page, including this one, is estimating rather than auditing.

12.1

How far can the environment sustain this?

A carrying-capacity model with three variables. Workload volume grows. Efficiency cuts the energy each unit of work needs. Clean supply grows to meet what is left. Equilibrium holds only while the first two, combined, stay below the third.

Net demand growth  =  (1 + g) · (1 − e) − 1
Equilibrium holds while   (1 + g) · (1 − e)  ≤  (1 + c)
g = workload growth  ·  e = efficiency gain  ·  c = clean supply growth

130%
35%
22%
—
Crossover
Net demand growth
—
per year, after efficiency
Efficiency needed
—
per year, to hold the line
Workload ceiling
—
growth the supply can absorb
The shortfall
—
percentage points per year
Figure E · AI electricity demand against clean supply reaching data centres Projected AI demand curve against clean supply curve with crossover point

12.2

What holds the equilibrium

Each condition below moves one variable in the equation above. The order is deliberate — it runs from what you control this week to what takes a decade and a parliament.

Bend g before you polish eWorkload growth · immediate · yours

Efficiency is losing a race it did not choose. At the default settings the industry needs a far larger annual efficiency gain than it is achieving, and the gap is made of workload volume, not model design. Cap agent step counts, route to small models by default, kill the retry tax. This is the only variable that responds in days.

Keep e compounding, and stop claiming it as victoryEfficiency · continuous · engineering

Quantisation, distillation, sparsity, better serving stacks and speculative decoding have delivered genuine order-of-magnitude gains and must continue. But an efficiency gain announced without the corresponding volume figure is a half-truth, and the half that is missing is the one that decides the answer.

Raise c with additional generation, not certificatesClean supply · years · procurement and policy

Buying existing clean electricity displaces another consumer onto fossil generation and changes nothing at system level. Only additional capacity, contracted ahead of the load it serves, moves c. Hourly matching makes the claim auditable; annual certificates do not.

Decouple the timing, not just the totalDemand flexibility · months · operations

A crossover is a peak problem before it is an annual problem. Grid-interactive data centres that curtail or shift training and batch inference into clean hours buy real years of runway without reducing a single unit of work done.

Measure, or forfeit the argumentDisclosure · precondition for everything above

None of these variables can be managed at the values they actually hold, because nobody publishes them. Independent estimates for the same model differ by an order of magnitude. Until per-model energy telemetry is standard disclosure, equilibrium is a claim, not a measurement — and this framework is a well-reasoned guess.

The honest summary. The environment can sustain AI adoption indefinitely at some rate. The question was never whether, but at what rate — and the current rate is set by capital allocation and product ambition, with the environmental constraint discovered afterwards through interconnection queues, water permits and local opposition rather than chosen deliberately in advance. Equilibrium is available. It is simply not what anyone is currently optimising for.

13 — Action

Suggestions to improve the environment

Tick what you will genuinely commit to. The figure at the bottom applies diminishing returns rather than adding percentages, because these measures overlap.

0%
Nothing selected yet. Start with the highest-value items — the first three usually carry most of the reduction.

The order matters. Right-sizing and retry reduction are behavioural, free and available today. Region and cooling choices are procurement decisions with a lead time of weeks. Grid and policy measures take years. Do the first tier while you argue about the third.

14 — Outlook

Predicted effects on the world environment

Figure A · Global data centre electricity, actual and projected Data centre electricity demand rising from 2020 to 2035 with your scaled contribution overlaid

Figure B · The same query, run on eight different grids Carbon emitted by one identical query across eight electricity grids

Identical compute. Identical answer. Eighteen times the emissions between the cleanest and dirtiest column. This is why siting is a bigger environmental decision than usage policy — and why it is made by people who never see a prompt.

Figure C · The scissors — why both camps are right Energy per task falling while total consumption rises

Efficiency is not reduction. Power per AI task is falling at a rate unprecedented in energy history, while total consumption climbs. Both statements are true, and each camp quotes only its own line. The gap between them is the rebound effect, and agentic workloads are its engine.

Electricity — the load is real, the share is smaller than the discourse suggests
  • Global data centre demand sits near 485 TWh in 2025 and is projected to roughly double to 945–950 TWh by 2030 — about 3% of world electricity. AI-focused facilities are the fastest-growing slice, projected to triple over the same period.
  • Data centre demand grew 17% in 2025 against 3% growth in overall electricity demand. The pressure is a rate-of-change problem, not yet a share-of-total problem.
  • Efficiency is improving unusually fast — power per AI task has been falling by roughly an order of magnitude a year. This is the strongest argument against straight-line extrapolation, and the strongest argument for Jevons-effect caution.
  • Net expectation to 2030: a genuine new load comparable to a mid-sized industrial economy, arriving faster than grids can decarbonise, but not a dominant driver of global emissions on its own.
Carbon — siting decides the outcome more than usage does
  • The same query emits roughly eighteen times more CO₂e on a coal-heavy grid than a hydro-dominant one. Where inference runs matters more than how often it runs.
  • Natural gas and coal are expected to meet a large share of the additional data centre demand to 2030, because new capacity is being built faster than clean generation can be connected.
  • Renewables still supply the largest slice of the growth, and small modular reactors enter the mix after 2030 — but the near-term gap is filled by whatever the local grid has spare.
  • Net expectation: AI's own emissions are modest at global scale; its indirect effect on the pace of grid decarbonisation, through interconnection queues and fossil plant retirement deferrals, is the larger risk.
Water and land — a local problem, not a global one
  • Water impact is highly concentrated. A single large facility can draw hundreds of thousands of gallons a day, which is trivial nationally and severe in a stressed basin.
  • Concentration is the mechanism: nearly half of global data centre electricity is consumed in the United States, with heavy clustering in a handful of regions. Ireland already dedicates around a fifth of national electricity to data centres.
  • Net expectation: expect local grid stress, water permitting fights and land-use disputes to become the binding constraint on AI expansion well before global carbon accounting does.
WHERE DATA CENTRE ELECTRICITY IS ACTUALLY CONSUMED United States 45% China 25% Europe 15% Rest 15% Ireland already devotes around a fifth of its national electricity to data centres. Virginia is near a quarter. A global average conceals the fact that the burden lands on a handful of counties, aquifers and substations.
The rebound risk — efficiency is not the same as reduction
  • Per-task energy is falling sharply while total consumption rises sharply. Both statements are true simultaneously, and each is used selectively by opposing camps.
  • Agentic workloads are the mechanism. A single agent run can consume tens to hundreds of times a chat query, because it issues many model calls and carries long context through each one.
  • Net expectation: the dominant environmental variable for the rest of this decade is not model efficiency but workload design — how many calls a task makes, and whether anyone is counting.

Where this framework is weak, stated plainly. Per-query energy figures are estimates, not measurements — no major lab publishes full telemetry, and independent estimates for the same model vary by an order of magnitude. Embodied carbon in chips, buildings and networks is excluded from the per-query figures and folded into a single crude amplifier. Water intensity varies by site and season far more than any single coefficient can capture. Treat every number here as a decision aid with wide error bars, not an audit result.

15 — Method

How the numbers are derived

Calculation chain
  • Energy is built from tokens, not from a flat per-query constant. Each model class carries a decode coefficient in watt-hours per output token and a prefill coefficient per input token, set roughly thirty times lower because prefill batches efficiently while decode runs the whole model once per token.
  • Calibration. The mid-tier coefficient reproduces a median near 0.31 Wh for a typical query, matching peer-reviewed estimates for optimised large-scale inference with an interquartile range of about 0.16–0.60 Wh. Published per-token measurements cluster at 0.0001–0.002 Wh, which brackets every coefficient used here.
  • Reasoning models add hidden thinking tokens to the decode count. Agentic runs multiply by sixteen internal model invocations, each re-reading the carried context — which is why context length hurts agents far more than it hurts chat.
  • Retries multiply the whole chain linearly — a failed answer costs full price.
  • Facility energy = IT energy × PUE. Carbon = facility kWh × grid intensity. Water = facility kWh × (on-site cooling coefficient + off-site generation coefficient scaled to grid carbon intensity).
  • Score bands each dimension against the rubric in section 05 and sums to 100.
Primary sources
  • International Energy Agency — Energy and AI (2025) and Key Questions on Energy and AI (2026): data centre demand trajectory, grid mix, regional concentration.
  • Joule (2026) — energy use of AI inference, efficiency pathways and test-time scaling: per-query medians and the effect of reasoning length.
  • Benchmarking studies on energy, water and carbon footprint of LLM inference (2025–2026): cross-model comparisons and eco-efficiency ranking.
  • Lawrence Berkeley National Laboratory and Carbon Brief: regional concentration and national share estimates.
Board pack Generates a print-ready executive summary — your score, footprint, model recommendation, equilibrium position and committed actions. Use your browser's Save as PDF in the print dialogue.